South African built. Enterprise focused.
+27 87 515 0952Company & product profilesContact us
Alphadot X
Alphadot X / Engineered monitoring & digital response

Protect the surface.
Preserve the asset.

Connect epoxy, glass, ceramic and rubber protection profiles with selected monitoring, qualified inspections, maintenance response and engineering evidence.

For mining and mineral-processing equipment.
Engineered solution proposed by Alphadot X · Powered by Lupin Technologies.

From indication to informed action

A signal matters
when it leads to
a controlled decision.

The measurement. The inspection. The person responsible. The evidence of what happened.

Our proposed approach combines selected monitoring points and material-specific inspection records with a structured maintenance-response workflow. It brings protection-system context, engineering evidence and action ownership into one operating story.

Alphadot X coordinates the digital implementation. Qualified instrumentation, integrity-engineering and NDT specialists establish the measurement methods, installation requirements and verification approach.

Material-specific protection intelligence

Four protection systems.
Different inspection questions.

Start with the lining, substrate and operating conditions. Then select the measurements and qualified inspections that can answer the actual engineering question.

Illustrative epoxy protective lining; supplied proposal illustration, not a client installation
Corrosion & selected chemical exposure

Epoxy lining

Coating and lining systems for compatible service on steel or concrete. Formulation, preparation, temperature and process chemistry determine suitability.

Inspection questions

Investigate: Blistering, pinholes, cracking, peeling and underfilm corrosion.

Assess: Visual coating survey, dry-film thickness and qualified continuity or adhesion assessment.

Electrical testing method and voltage require approval for the specific coating and service history.

Explore epoxy in the demo ↗
Illustrative glass protective lining; supplied proposal illustration, not a client installation
Chemical duty & product purity

Glass lining

Glass-lined vessels for compatible chemical processes, with inspection focused on the barrier, nozzles, attachments and repaired areas.

Inspection questions

Investigate: Chips, cracks, pinholes, thermal damage and defects around nozzles or repair plugs.

Assess: Qualified visual inspection, glass thickness measurement and OEM-approved testing.

Glass and repaired areas require manufacturer-specific procedures; test methods are not interchangeable.

Explore glass in the demo ↗
Illustrative ceramic protective lining; supplied proposal illustration, not a client installation
Abrasion & erosion

Ceramic lining

Wear-resistant surfaces for selected chutes, cyclones and transfer equipment. Tile design, loading and attachment influence the assessment.

Inspection questions

Investigate: Wear, broken or missing tiles, impact damage and attachment deterioration.

Assess: Wear mapping, visual and attachment surveys; compatible engineered wear sensing where approved.

Embedded wear sensing needs a suitable installation and supplier interface. It does not establish every tile or bond condition.

Explore ceramic in the demo ↗
Illustrative rubber protective lining; supplied proposal illustration, not a client installation
Impact, abrasion & selected chemical service

Rubber lining

Flexible protective linings for compatible equipment and process duties. Wear, chemical ageing and bond integrity are assessed separately.

Inspection questions

Investigate: Wear, tearing, blistering, lifting, suspected separation and exposed substrate.

Assess: Visual condition mapping, appropriate acoustic investigation and qualified follow-up inspection.

External steel-wall readings do not confirm rubber adhesion or certify the lining as intact.

Explore rubber in the demo ↗

Illustrative lining images supplied in Alphadot X’s technical proposal. They are not photographs of a client installation.

One operating picture. Complementary evidence.

A steel-wall measurement, a leakage indication and a lining inspection describe different conditions. A healthy reading at one point does not certify the full protective system. Materials, thresholds, test methods and operating decisions require competent engineering approval.

01 / Complementary methods

Different indications.
The right evidence.

Steel-wall loss, lining condition and escaped fluid are different engineering questions. The assessment defines the appropriate sensing and inspection approach for each.

01 / Steel substrate

Local wall-thickness monitoring

Selected external ultrasonic points can provide repeated steel-thickness readings for review against qualified reference measurements.

Coverage is limited to the measurement footprint. Steel-wall readings do not establish lining adhesion or the condition of epoxy, glass, ceramic or rubber barriers.

02 / Containment

Leakage indications

Suitable indicators can flag local fluid contact along an assessed containment or leak route, prompting investigation.

Placement, fluid compatibility and operating conditions matter. A leakage indication is not a confirmed diagnosis of lining failure.

03 / Protection system

Qualified condition inspection

Visual assessment, appropriate acoustic investigation and targeted NDT provide the evidence needed to investigate suspected defects.

Methods depend on material, geometry, access and competent engineering interpretation.

02 / Start with the asset

Define the equipment.
Understand the limits.

A focused first assessment can begin with a rubber-lined process tank and a critical slurry-pipeline section. Expansion to epoxy-coated tanks, glass-lined vessels or ceramic-lined equipment requires its own engineering and inspection scope.

Concept section of a process tank showing external UT points, a suspected lining defect, a containment leakage indicator and baseline inspection
Rubber-lined process tank

Combine selected shell measurements and containment indications with a baseline lining survey and qualified inspection records.

Concept section of a slurry pipeline elbow showing steel wall, rubber lining, a permanent UT reference point and an area requiring targeted NDT
Slurry pipeline & elbow

Assess high-wear locations, measurement footprints and adjacent areas requiring independent inspection.

Concept illustrations adapted from Alphadot X’s technical proposal. Positions are indicative, not site drawings or proof of installed coverage.

03 / The proposed connected architecture

From the field
to the command centre.

A site-specific design connects approved measurement interfaces to the digital workflow while preserving the plant’s operational authority.

01

Measurements & inspection evidence

Selected UT points · leakage indicators · qualified visual and NDT findings

02

Industrial edge & approved OT boundary

Acquisition · timestamps · data quality · local buffering · authorised data transfer

03

ADX Surface Intelligence

Proposed telemetry integration · condition trends · engineering-approved rules · event context

LupinAsset

Equipment identity, location and condition history.

LupinServe

Investigation ownership, inspection coordination and corrective work.

LupinScript

Controlled NDT reports, photographs, drawings and decision evidence.

04

Surface Integrity Command Centre

A proposed shared view for control-room, engineering and maintenance teams.

The command-centre demo illustrates this experience. Industrial adapters, analytics and cross-product connections are project deliverables requiring engineering and integration validation.

04 / The response workflow

Follow the indication
through to verification.

Keep a suspected condition, a confirmed finding and a verified close-out distinct throughout the record.

01

Observe & validate

Review measurement identity, timestamp, quality and sensor availability before interpreting the signal.

02

Locate & investigate

Bind the indication to an asset and monitoring point. An authorised engineer decides the investigation required.

03

Assign & document

Coordinate inspection and corrective work with named owners, due dates and linked technical evidence.

04

Verify & retain

Record the reviewed outcome, repair or no-defect decision and retain the evidence of closure.

05 / Explore the interactive experience

Take a seat in
the demo control room.

Explore 14 synthetic assets, four material libraries, material profiles, inspections, work and engineering records. Select a lining type, review its inspection questions and follow a sample finding through the workflow.

Interactive frontend demonstration. No live sensors, plant connection or connected Lupin deployment.

06 / From assessment to operational handover

Engineer the scope.
Prove the workflow.

A defined pilot brings engineering, instruments, digital integration and operational acceptance into a coordinated delivery plan.

01 / Assess

Site & baseline

Review candidate equipment, damage mechanisms, drawings, inspection history, access and existing systems.

02 / Design

Engineering & interfaces

Qualify the sensing method, supplier specifications, measurement coverage and approved OT data path.

03 / Integrate

Build & test

Develop the agreed adapters, configure workflows and test measurement identity, data quality and event handling.

04 / Validate

Commission & support

Compare with qualified reference evidence, complete acceptance, train the team and hand over the agreed support model.

Operational control stays with the plant.

Minimum allowable thickness, thresholds, fitness-for-service decisions and operating actions belong to the competent site authorities. The proposed solution is an advisory and maintenance-response layer. Qualified inspection, statutory controls and approved safety shutdowns remain independent.

Technical reference points

Qualify the method
with the right specialist.

These manufacturer resources help explain different inspection and wear-monitoring approaches. They are reference material, not a claim of partnership, installed equipment or confirmed integration.

Start with the right questions

Bring us the asset.
Let’s define
the assessment.

Tell us the asset type, process environment, existing monitoring and inspection arrangements, and the outcome your team wants to assess.

  • Which tank, pipeline or equipment class is in scope?
  • Which deterioration mechanism needs investigation?
  • What records and approved system interfaces are available?
  • Who owns engineering review and operational acceptance?
Discuss a site assessment ↗

Send your assessment enquiry through our website. Technical and commercial scope follows the site assessment.

+27 87 515 0952
Useful distinctions

Before you explore.

Is the demo connected to a real mine?

No. Measurements, assets, records and people in the hosted demonstration are synthetic. Browser interactions do not change plant equipment or live Lupin systems.

Does one sensor detect every lining or structural defect?

No. Measurement methods have different targets and coverage. External UT provides local steel-thickness information; lining adhesion and other findings require suitable qualified inspection.

Does this replace a plant safety system?

No. The proposed solution supports condition review, evidence and response coordination. Approved plant alarms, operational decisions and safety shutdowns remain under the site’s independent control.

How is a pilot priced and scheduled?

After the candidate assets, engineering scope, instruments, access, interfaces and acceptance requirements are defined. Hardware and specialist services require their own confirmation; the public demonstration is not a quotation or delivery commitment.